LumafluorRetroBeads——逆向示蹤首先

RetroBeads™逆向示蹤熒光微粒是Lumafluor 公司*的逆向示蹤產品,且是目前weiyi證實有效的示蹤微粒(該產品的有效性經數百篇從無脊椎動物到哺乳動物實驗的研究論文證實),目前Lumafluor 公司的綠色和紅色熒光示蹤微粒產品只能從本公司采購。
  該示蹤產品體內注射高度集中不易擴散,信號強,對活細胞或活體無毒,且存留時間大于一年,與大多順向示蹤劑、原位雜交檢測技術、免疫組化技術兼容。


部分產品信息如下:

 

貨號品名包裝目錄價*品牌
78R170Red Retrobeads™100µl36672200lumafluor2017
78R180Red Retrobeads™ IX100µl36672200lumafluor2017
78G180Green Retrobeads™ IX100µl36672200lumafluor2017

該說明書總結了大多數使用熒光膠乳微球(beads)作為神經元逆向示蹤劑的操作流程,其中關于綠色beads的信息請在本說明書末尾查看。更為詳盡的信息請參考Katz, L.C.的以下論文:

1. Katz, L.C., Burkhalter, A., and Dreyer, W.D. Fluorescent latex microspheres as a retrograde neuronal marker for in vivo and in vitro studies of visual cortex. Nature 310: 498-500 (1984)

2. Katz, L.C. and Iarovici, D.M. Green fluorescent latex microspheres: a new retrograde tracer. Neuroscience 34: 511-520 (1990)
如有疑問,請郵件咨詢info@lumafluor.com 或咨詢:919 801-6244Lumafluor中國經銷商上海起發實驗試劑有限公司。

LumafluorRetroBeads操作說明

一、包裝與稀釋:

Lumafluor beads包裝于一支密封的小瓶內,內含的濃縮beads懸浮于蒸餾水中。如使用紅色Beads作為神經通路的逆向示蹤,其稀釋方法推薦采用:大鼠視皮層內可采用14比例進行稀釋而不減少Beads的熒光標記強度和質量。然而對于實驗我們不推薦使用稀釋的Beads而使用原液進行注射示蹤。除蒸餾水外,常規的鹽溶液如NaClKCl溶液也可作為稀釋液。如使用綠色Beads,則強烈建議使用原液,無需稀釋。

二、儲存

    為避免蒸發Bead溶液應存放于冰箱內4度冷藏,切忌勿冷凍! 冷凍的Beads將失去效用,無法使用。而變干的beads同樣也無法使用(無法重懸),該產品并無明顯的使用期限,如按要求存放可保存數年。

 

三、注射:

    Beads使用壓力注射,如1 mlHamilton微量注射器或氣壓注射系統,如需小區域微量注射(30-50 nl),可采用末端30-50 um直徑的玻璃電極注射,而常規的逆向示蹤(注射量0.1-0.3 ul)可使用更大直徑的玻璃電極。盡管如此,即使注入更大的劑量,Beads,也不會明顯從注射位點擴散(通常擴散距離少于1mm),因此,為盡量*標記投射到一個較大神經核團的神經元,需使用多點注射。盡管Beads帶有負電荷,但是不建議采用離子滲透法注入示蹤Beads

四、存活時間:

    在大多數恒溫脊椎動物系統中,檢測Beads的zui短有效時間是24小時,在48小時內標記強度隨著體內注射時間而延長,48小時以后熒光強度基本保持恒定。而在冷血動物中,檢測Beads的時間推薦為1周。目前并未檢測Beads的zui長可檢測期,然而在Beads的熒光強度和質量至少可保持在體內14個月以上不變,而細胞可能會被yongjiu標記。目前并未發現Beads在動物或神經元中表現出毒性作用的報道。

五、固定和處理:

    標準的固定方法是:0.1 M PBS沖洗或灌注后在4%的多聚甲醛(0.1 M PBS配制,pH 7.4)中固定,用戊二醛固定會產生大量的組織自發熒光,妨礙Beads標記的神經元,并且綠色Beads在戊二醛固定的組織中將*觀察不到,因此應盡量避免采用。如采用冰凍切片,切片應用PBS漂洗后用明膠包被的載玻片貼片晾干,在*風干后,再用二甲苯透明1分鐘,然后用熒光封片劑(FluoromountKrystalon)封片。Fluoromount可從Atomergic Chemetals Corp., Farmingdale, NY)公司購買; Krystalon可從

Harleco (EM IndustriesGibbstown, NJ)購買。切片只可短期暴露在乙醇或二甲苯中,但是長時間暴露(大于5分鐘)會損壞BeadsBeads 對甘油非常敏感,在甘油環境中熒光會迅速萃滅,因此切忌使用甘油類封片劑,如無法避免,還可采用水楊酸甲酯代替甘油作為封片劑。封片后的切片如存放于黑暗環境中,熒光Beads標記的細胞可保持一年不萃滅(但是切片的自身熒光背景會增加)。迄今為止,還沒有成功采用塑膠材料包被Beads標記的組織的記錄。

  • 觀察:

    紅色Beads中的染料為羅丹明,因此所有與羅丹明匹配的熒光濾鏡均可使用,部分老的尼康公司的羅丹明濾鏡因背景較高,可能導致無法觀察到熒光Beads,通常Zeiss Leitz的標準羅丹明濾鏡可獲得較好的觀察效果。而大多綠色熒光濾鏡均可較好地觀察綠色Beads的熒光結果,設置為熒光黃的濾鏡可獲得較強的明亮熒光,但是同時也帶來較高的背景干擾。較寬波段的熒光濾鏡比窄波段的熒光濾鏡可以獲得更強的熒光信號。在長時間的觀察和拍照下Beads的熒光也不會淬滅。

  在低倍數或低數值孔徑物鏡下( X4, X10)通常難以觀察到Bads的熒光信號,只有細胞被顯著標記,X10的油鏡(數值孔徑大于0.4)或者更大倍數的物鏡才可觀察到。通常情況下,X 25的油鏡可以清晰地觀察到低倍鏡下無法觀察到的標記細胞。物鏡的選用對綠色熒光Beads尤其重要。在做出實驗失敗的決定前(在目標區域無法觀察到標記細胞),可先用油鏡仔細觀察注射位點附近的細胞是否被標記,此處應該觀察到大量的標記細胞。

對使用綠色熒光Beads標記的額外提醒:目前已發現綠色熒光Beads在年青動物比年老動物中標記更為理想的情況,此外,年青動物的組織自發熒光(背景)也更低,因此,假如可以的話,在使用綠色熒光Beads做逆向標記實驗時請盡量使用年輕動物。

因為綠色熒光Beads的激發光段比紅色熒光Beads短,因此組織自發熒光是個麻煩,因此,應采用減少自發熒光的步驟以獲得更理想的實驗結果,這些方法有:(1)使用更薄的切片,如30微米比4050微米理想;(2)使用年青的動物;(3)封片后立即觀察拍照(隨著時間增加背景也會增加)。

 

!!!!!!!!!!!!!!!!!!!

    對使用色熒光Beads標記的額外提醒:目前已發現綠色熒光Beads在年青動物比年老動物中標記更為理想的情況,此外,年青動物的組織自發熒光(背景)也更低,因此,假如可以的話,在使用綠色熒光Beads做逆向標記實驗時請盡量使用年輕動物。

    因為綠色熒光Beads的激發光段比紅色熒光Beads短,因此組織自發熒光是個麻煩,因此,應采用減少自發熒光的步驟以獲得更理想的實驗結果,這些方法有:(1)使用更薄的切片,如30微米比4050微米理想;(2)使用年青的動物;(3)封片后立即觀察拍照(隨著時間增加背景也會增加)。

 

Protocols for Use of Fluorescent Latex Microspheres (rev. 11/07)

This sheet summarizes most of the procedures for using fluorescent latex microspheres, or "beads" as a retrograde neuronal tracer. Special information about green beads is at the end of this protocol. Further details are presented in: Katz, L.C., Burkhalter, A., and Dreyer, W.D. Fluorescent latex microspheres as a retrograde neuronal marker for in vivo and in vitro studies of visual cortex. Nature 310: 498-500 (1984), and Katz, L.C. and Iarovici, D.M. Green fluorescent latex microspheres: a new retrograde tracer. Neuroscience 34: 511-520 (1990). Questions, problems, or comments concerning the use of this material can be directed to: info@lumafluor.com or phone 919 801-6244.

 

How supplied: The enclosed vial(s) contains a concentrated solution of beads suspended in distilled water. If red beads are being used for retrograde tracing of neuronal pathways, the solution can be used as is, or diluted. In rat visual cortex, dilutions of 1:4 do not appear to reduce the quality or extent of retrograde labeling when using red beads. However, for initial experiments we strongly recommend using the solution full strength. In addition to distilled water, standard salt solutions (NaCl, KCl) can be used as diluents. The green beads, as supplied, are compley prepared for retrograde tracing experiments. Dilution of green beads is not recommended.

Storage: The bead solution should be stored in a humidified container, in a refrigerator, to prevent evaporation. Do not freeze! Beads that have been frozen will not work, and cannot be rescued. If the beads dry out, they cannot be reconstituted. No shelf life has been established for this material, but, when properly stored, it remains good for several years.

Application: Beads are best injected using pressure (e.g. a 1 ml Hamilton syringe, or pressurized air injection system). For local circuit work, very small volumes (30-50 nl) have been injected through glass pipettes with 30-50 mm diameter tips. For routine retrograde tracing, larger volumes (0.1-0.3 ml) and larger diameter pipette tips are used. However, even with large injections beads do not diffuse far from the injection site (usually less than 1 mm). Thus in order to label all or most of the neurons projecting to a large structure, several injections should be made. Iontophoretic application of beads is not recommended as an effective means to deliver the tracer. However, the beads do have a net negative charge.

Survival times: The minimum effective post-injection survival time in most warm-blooded vertebrate systems is approximay 24 hours. Labeling intensity increases with longer survival, up to 48 hours. After 48 hours, no increase (or decrease) in labeling intensity is observed. These values may be considerably different in cold-blooded animals, and initial survival times of a week are recommended. The maximum survival time has not been established, but labeling is unchanged in either quality or extent even after 14 month survival times. Cells probably are permanently marked. No toxic effects on either animals or neurons have been observed.

Fixation and processing: Standard fixation is a 0.1 M phosphate buffer wash followed by 4% paraformaldehyde in 0.1 M phosphate buffer (pH 7.4). Glutaraldehyde will produce substantial tissue autofluorescence which may obscure bead-labeled neurons, and should be avoided if possible. Green beads will be compley invisible in glutaraldehyde fixed material. Frozen sections are collected in phosphate buffer, mounted on gelatin-coated slides, and air-dried. After complete drying, slides can be cleared in xylene for 1 minute, and covers lipped with Fluoromount or Krystalon. Fluoromount is available from Atomergic Chemetals Corp., Farmingdale, NY; Krystalon from Harleco (EM Industries),Gibbstown, NJ. Brief exposures to alcohols and xylenes are not harmful, but long exposures (over 5 minutes) will destroy the beads. Beads are very sensitive to glycerol, and will fade rapidly if mounted in glycerol-containing solutions. Methyl salicylate is preferable to glycerol in situations where non-permanent clearing/mounting agents are indicated. If slides are kept in the dark, the labelling in cells will not fade for at least one year (although background autofluorescence may increase substantially). Thus far, attempts to retain bead labeling after plastic embedding have not been successful.

Observation: The dye in the red beads is rhodamine, thus any fluorescence filter set for rhodamine can be used. Some older Nikon rhodamine filter sets give a very high background, which can make labeled cells invisible. Good results have been obtained with both Zeiss and Leitz standard rhodamine filters. For green beads, a wide-band fluorescein filter works well. Filter sets for Lucifer yellow give a more intense signal, but at the expense of higher background. Narrow-band fluorescein filters will give a much weaker signal than a broad-band filter. Beads do not fade appreciably even after long periods of observation or photomicrography.

Labeling is usually not visible with low power, low numerical aperture dry objectives (e.g. X4, X10). If cells are strongly labeled, a X10 immersion objective (numerical aperture of 0.4 or greater), or higher power dry objectives, will usually reveal the cells. However, frequently a X25 immersion objective will reveal very clearly labeled cells that lower power objectives miss. These caveats are especially true for green beads. Before deciding that an experiment did not work, examine sections in the vicinity of the injection site with immersion objectives. Numerous locally labeled cells should be present.

Additional information for green bead users: In work that has been done so far, it appears that younger animals transport the label better than older animals. In addition, tissue autofluorescence is lower in the younger animals. Therefore, it is advisable to use younger animals, if possible, in experiments involving green beads.

Because the green beads are excited at shorter wavelengths than red beads, tissue autofluorescence is a greater problem. Therefore, efforts to minimize autofluorescence will produce a better contrast signal. Ways to reduce autofluorescence include: 1) using thinner sections (e.g. 30 um rather than 40 or 50) 2) using younger animals, and 3) examining sections promptly after coverslipping (background increases over time).

 

 

Information

For Reliable, Robust Retrograde Transport, There's Only One Choice: RetroBeads™ from Lumafluor.


RetroBeads™ from Lumafluor--the original microspheres for retrograde tracing and the only microspheres proven effective where it counts: in your experiments. Green and Red fluorescent RetroBeads™ are available exclusively from Lumafluor.

Do not be misled by the unsubstantiated claims of other suppliers!
No matter what they call their products, only Retrobeads™ from Lumafluor have been proven effective by hundreds of published papers in systems ranging from invertebrates to primates, and everything in between.

Lumafluor Retrobeads™:

  • Highly confined injections--superb for detailed connectivity studies.
  • Persist indefiniy (> 1 year!) in living cells, nontoxic.
  • Compatible with most other anterograde tracers, in situ hybridization, and immunohistochemsitry.


 


 

Retrosphere™ Color: Excitation Max (nm)Emission Max (nm)
Green460505
Red530590

 

New!

Retrobeads™ IX: Retrobeads™ deliver bioactive agents (such as neurotrophins and neurotransmitter agonists/antagonists) to localized regions; retrograde transport allows determining which neurons were exposed to the agents [Riddle et al. Nature 378:189, 1995 and Quattrochi et al. Science 245:984, 1989].

Retrobeads™ IX are specially prepared to facilitate adsorption of proteins and other bioactive compounds. Retrobeads™ IX are also more effective tracers in primate systems than standard Retrobeads™.

上海起發實驗試劑有限公司專業代理lumafluor全線產品 。并被有大量現貨,歡迎廣大科研人員訂購 4006551678

 Lumafluor 中國代理, Lumafluor 上海代理, Lumafluor 北京代理,Lumafluor 廣東代理, Lumafluor 江蘇代理Lumafluor 湖北代理,Lumafluor 天津,Lumafluor 黑龍江代理,Lumafluor 內蒙古代理,Lumafluor 吉林代理,Lumafluor 福建代理, Lumafluor 江蘇代理, Lumafluor 浙江代理, Lumafluor 四川代理,

 

上海起發實驗試劑有限公司
地址:上海浦東川沙鎮川沙路6619號上海起發實驗試劑有限公司
郵箱:xs1@78bio.com
傳真:021-50724961
關注我們
歡迎您關注我們的微信公眾號了解更多信息:
歡迎您關注我們的微信公眾號
了解更多信息
主站蜘蛛池模板: 夜夜躁狠狠躁日日躁孕妇 | 欧美永久视频 | 天天噜夜夜噜 | 男女黄床上色视频 | 亚洲顶级裸体av片 | eeuss鲁片一区二区三区小说 | www成人在线 | 天堂在线一区二区 | 双乳奶水饱满少妇呻吟免费看 | 国产高清在线精品 | 正在播放酒店约少妇高潮 | 劲爆欧美第一页 | 越做高潮越喷奶水视频 | 欧美视频网址 | 午夜不卡无码中文字幕影院 | 视频一区二区无码制服师生 | 粉嫩欧美一区二区三区高清影视 | 婷婷色小说 | 国产精品人成在线观看 | 九九免费视频 | 欧美一a一片一级一片 | 精品无码成人网站久久久久久 | 久久短视频 | 黄 色 软件 成 人在线 | 日本黄色美女网站 | 日韩国产精品一区二区 | 美女极度色诱视频国产免费 | 亚洲人成网线在线播放va蜜芽 | 国产aⅴ一区二区三区 | 国产精品全国免费观看高清 | 五月婷婷开心中文字幕 | 午夜啪啪网站 | 性开放少妇xxx视频 久久996re热这里有精品 | 在线视频精品中文无码 | 欧美国产成人精品 | 久操av在线 | 国产无套内射久久久国产 | 亚洲区精品区日韩区综合区 | 60岁欧美乱子伦xxxx | 欧美日韩在线视频免费 | 国产人妻aⅴ色偷 | 色一情一乱一乱一区99av | 國产一二三内射在线看片 | 成人性生交大片免费看4 | 成人亚洲a片v一区二区三区蜜臀 | 自拍一级片 | 亚洲午夜福利精品无码不卡 | 成人精品一区二区户外勾搭野战 | 亚洲美女做爰av人体图片 | www国产成人免费观看视频 | 在线岛国片免费无码av | 黄色一级片久久 | 爱爱免费网站 | 色香蕉在线 | 国产成人精品亚洲男人的天堂 | 国产女主播在线一区二区 | 久草在线在线精品观看 | 舌吻激情大尺度做爰视频 | 亚洲 欧美 动漫 少妇 自拍 | 国内精品久久久久久久影视红豆 | 久久久成人999亚洲区美女 | 国产亚洲日韩在线a不卡 | 国产亚洲精品久久yy50 | 高清不卡视频 | 日韩欧美精品中文字幕 | 亚洲综合站 | 人妻夜夜爽天天爽三区麻豆av网站 | 久久久久久久久久久影院 | 欧美日韩一区二区三区四区在线观看 | 激情午夜视频 | 日日干日日草 | 国语粗话呻吟对白对白 | 西西人体大胆无码视频 | 国产人妻精品一区二区三区不卡 | 日本特黄一级片 | 亚洲自偷自拍另类12p | 熟女肥臀白浆大屁股一区二区 | 女人被躁到高潮免费视频软件 | 亚洲国产成人精品无码区在线 | 欧美一区二区三区久久综 | 麻豆网站在线观看 | 久久在线免费观看 | 国产av无码日韩av无码网站 | 无码人妻丝袜视频在线播免费 | 夜夜澡人摸人人添人人看 | www夜插内射视频网站 | 欧美国产成人精品一区二区三区 | 福利在线播放 | 亚洲精品久久久蜜桃动漫 | 欧美大片免费观看在线观看网站推荐 | 一级肉体全黄裸片 | 精品入口麻豆88视频 | 午夜寂寞视频无码专区 | 亚洲aⅴ天堂av天堂无码app | 国产女人喷浆抽搐高潮视频 | 在线观看欧美亚洲 | 91在线网站 | 日韩午夜精品免费理论片 | 男人天堂v|